Table 5-4
pd.conf file values (continued)
ActionPossible valuesDefault valueSetting
This keyword is reserved for internal use.
Note: Do not change this setting unless directed
to by a Symantec Technical Support
representative.
PDALIGN
Specifies the number of minutes before the
optimized duplication times out. Indicated in
minutes.
The value expressed
in minutes
N/AOPTDUP_TIMEOUT
This keyword is reserved for internal use.
Warning: Changing this value can reduce
capacity and decrease performance. Modify this
setting only if directed to do so by Symantec
support representative.
N/AN/ASEGKSIZE
Determines the smallest size file (in KBs) that
NetBackup segments. Files smaller than the
threshold are combined into a single large
segment to reduce the overhead of managing
many small segments. However, such segments
have less chance of being deduplicated.
Caution: Large numbers of files smaller than
the threshold may adversely affect backup
performance.
From 1 to the
practical system
limit
16MINFILE_KSIZE
Specifies that NetBackup should use the
PureDisk Remote Office Agent dynamic
segmentation deduplication algorithm. Enabling
it means that the data that is backed up is
globally deduplicated with each other. If disabled
(set to 0), PDDO uses a static 128KB
segmentation algorithm for deduplication.
Caution: Changing the default segmentation
algorithm most likely causes the next set of
backups to not deduplicate with the existing
storage pool data. Subsequent backups then
deduplicate using the PDRO algorithm.
1 (on) or 0 (off)1MATCH_PDRO
Determines the maximum bandwidth that is
allowed for optimized duplication. The value is
specified in KBytes/second.
0 (no limit) to the
practical system
limit
0OPTDUP_BANDWITH
Configuring deduplication
Editing the deduplication configuration file
62
Kommentare zu diesen Handbüchern